Part number: PDPN-1112-G
Image is representative (may not be specific item).
Collections: All, Analytical, Automation, Automation consumables, Autosampler syringes, CTC Analytics, CTC RTC, LEAP PAL accessories, Literature - All, Literature - Analytical, Literature - Automation, Part Number Lists, Replacement Parts, Select by instrument - Analytical, Support Items, Syringes, Thermo Scientific, Thermo Scientific TriPlus, Thermo Scientific TriPlus RSH
Category: Analytical, Automation, Automation consumables, Autosampler, autosampler syringes, CTC, CTC Analytics, CTC RTC, HDX, LEAP, Needles, PAL, Removable Needle, Replacement Needles, RSH, Support, Syringes, Thermo, Thermo Scientific, Thermo Scientific TriPlus, Thermo Scientific TriPlus RSH
Type: Part Number Lists
Download: Part Number List - Replacement needles for CTC PAL autosampler syringes [PDF]
Find in table:
Part number (*needle and plunger kit) |
Part description and detail | Needle gauge | Needle OD (mm) | Needle length (mm) | Needle tip | Pack size | For use with syringe(s) |
---|---|---|---|---|---|---|---|
For LC | |||||||
031590 | 5.7 cm 1.07 mm OD 0.65 mm ID LC tipped needle for 5-10 mL CTC RTC and Thermo RSH syringes PK2 | 19 | 1.07 | 57 | LC | 2 | 008951 |
037880 | 5.7 cm 0.72 mm OD LC tipped needle for 10 µL CTC RTC and Thermo RSH syringes PK2 | 22 | 0.72 | 57 | LC | 2 | 002880 |
038250 | 5.1 cm 0.72 mm OD LC tipped needle for 25-500 µL syringes PK5 | 22 | 0.72 | 51 | LC | 5 | 005330, 006330 |
039280 | 5.7 cm 0.72 mm OD LC tipped needle for 1-2.5 mL CTC RTC and Thermo RSH syringes PK2 | 22 | 0.72 | 57 | LC | 2 | 008151 |
For GC | |||||||
033780* | 5.7 cm 0.63 mm OD cone tipped needle for 0.5 µL NanoVolume CTC RTC and Thermo RSH syringes PK1 | 23 | 0.63 | 57 | Cone | 1 | 000480 |
034780* | 5.7 cm 0.63 mm OD cone tipped needle for 1.0 µL NanoVolume CTC RTC and Thermo RSH syringes PK1 | 23 | 0.63 | 57 | Cone | 1 | 000680 |
036011 | 5 cm 0.63 mm OD cone tipped needle for 5 µL syringes PK2 | 23 | 0.63 | 50 | Cone | 2 | 001984 |
036871 | 5.7 cm 0.63 mm OD cone tipped needle for 5 µL CTC RTC and Thermo RSH syringes PK2 | 23 | 0.63 | 57 | Cone | 2 | 001871 |
036873 | 8.5 cm 0.47 mm OD cone tipped needle for 5 µL CTC RTC and Thermo RSH syringes PK2 | 23 | 0.63 | 85 | Cone | 2 | 001873 |
037787 | 5 cm 0.63 mm OD cone tipped needle for 10 µL CTC/Thermo syringes PK2 | 23 | 0.63 | 50 | Cone | 2 | 002984, 0029841 |
037871 | 5.7 cm 0.63 mm OD cone tipped needle for 10 µL CTC RTC and Thermo RSH syringes PK2 | 23 | 0.63 | 57 | Cone | 2 | 002871, 002872 |
037873 | 8.5 cm 0.63 mm OD cone tipped needle for 10 µL CTC RTC and Thermo RSH syringes PK2 | 23 | 0.63 | 85 | Cone | 2 | 002873, 002874 |
033772* | 5 cm 0.63 mm OD cone tipped needle for 0.5 µL NanoVolume CTC/Thermo syringes | 23 | 0.63 | 50 | Cone | 1 | 000492 |
031535 | 8 cm 0.47 mm OD cone tipped needle for 10 µL CTC/Thermo syringes PK3 | 26 | 0.47 | 80 | Cone | 3 | 0029931 |
036875 | 5.7 cm 0.47 mm OD cone tipped needle for 5 µL CTC RTC and Thermo RSH syringes PK2 | 26 | 0.47 | 57 | Cone | 2 | 001875 |
036877 | 8.5 cm 0.47 mm OD cone tipped needle for 5 µL CTC RTC and Thermo RSH syringes PK2 | 26 | 0.47 | 85 | Cone | 2 | 001877, 002877, 002878 |
0371010 | 5 cm 0.47 mm OD cone tipped needle for 10 µL syringes PK2 | 26 | 0.47 | 50 | Cone | 1 | 002982, 002985 |
037875 | 5.7 cm 0.47 mm OD cone tipped needle for 10 µL CTC RTC and Thermo RSH syringes PK2 | 26 | 0.47 | 57 | Cone | 2 | 002875, 002876 |
038732 | 5 cm 0.47 mm OD cone tipped needle for 25-500 µL CTC/Thermo syringes PK2 | 26 | 0.47 | 50 | Cone | 2 | 005333 |
038749 | 5 cm 0.47 mm OD side-hole dome tipped needle for 25-500 µL syringes PK2 | 26 | 0.47 | 50 | Side-hole | 2 | 003988 |
033770* | 5 cm 0.47 mm OD cone tipped needle for 0.5 µL NanoVolume CTC/Thermo syringes PK1 | 26 | 0.47 | 50 | Cone | 1 | 000490 |
034905* | 5 cm 0.63 mm OD cone tipped needle for 2.0 µL NanoVolume CTC/Thermo syringes PK1 | 23 | 0.63 | 50 | Cone | 1 | 000790 |
Septa, caps and liners play a key role in the storage and preparation of samples. They securely seal samples from the external environment while simultaneously allowing injection by sampling needles.
Cap types
Crimp caps |
|
Screw caps |
|
Snap caps |
|
Septa suitability with chemicals
The table below summarizes the suitability of each septa material with a range of chemicals, this can vary based on factors such as temperature, molecular weight and solvent concentration.
Filter by chemical:
|
PTFE |
PTFE/silicone |
PTFE/silicone/PTFE |
Viton |
Silicone |
Silicone/FEP |
Silicone/polyimide |
Butyl |
Foam (PTFE/polyethene foam) |
---|---|---|---|---|---|---|---|---|---|
Acetonitrile |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
|
✓ |
Hydrocarbons |
✓ |
|
✓ |
|
✓ |
✓ |
✓ |
|
✓ |
Methanol |
✓ |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
Benzene |
✓ |
|
✓ |
✓ |
|
✓ |
✓ |
|
✓ |
THF |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
Toluene |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
DMF |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
✓ |
DMSO |
✓ |
✓ |
✓ |
|
✓ |
✓ |
|
|
✓ |
Ether |
✓ |
✓ |
✓ |
|
|
✓ |
✓ |
|
✓ |
DCM |
✓ |
|
✓ |
✓ |
|
✓ |
✓ |
|
✓ |
Alcohols (ethanol) |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
Acetic acid |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
✓ |
Acetone |
✓ |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
Phenol |
✓ |
✓ |
✓ |
|
|
✓ |
✓ |
✓ |
✓ |
Cyclohexane |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
Septa compatibility with applications
This table provides a summary of the suitability of our septa materials to a variety of applications.
|
PTFE |
PTFE/silicone |
PTFE/silicone/PTFE |
Viton |
Silicone |
Silicone/FEP |
Silicone/polyimide |
Butyl |
Natural rubber |
---|---|---|---|---|---|---|---|---|---|
Temperature range |
Up to 260°C |
-40°C to 250°C |
-40°C to 250°C |
-40°C to 260°C |
-40°C to 250°C |
-40°C to 250°C |
-40°C to 300°C |
-50°C to 150°C |
0°C to 90°C |
Multiple injections |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
No |
No |
Price |
Very economical |
Economical |
Most expensive |
Economical |
Very economical |
Economical |
Expensive |
Economical |
Most economical |
Suitable for storage |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
No |
Yes |
Best for |
|
|
|
|
|
|
|
|
|
Please refer to the brochure (includes part number lists) for more items.
View full product details
Septa, caps and liners play a key role in the storage and preparation of samples. They securely seal samples from the external environment while simultaneously allowing injection by sampling needles.
Septa must be chemically compatible with your sample and solvent to ensure they provide an effective seal.
Septa suitability with chemicals
The table below summarizes the suitability of each septa material with a range of chemicals, this can vary based on factors such as temperature, molecular weight and solvent concentration.
Filter by chemical:
|
PTFE |
PTFE/silicone |
PTFE/silicone/PTFE |
Viton |
Silicone |
Silicone/FEP |
Silicone/polyimide |
Butyl |
Foam (PTFE/polyethene foam) |
---|---|---|---|---|---|---|---|---|---|
Acetonitrile |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
|
✓ |
Hydrocarbons |
✓ |
|
✓ |
|
✓ |
✓ |
✓ |
|
✓ |
Methanol |
✓ |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
Benzene |
✓ |
|
✓ |
✓ |
|
✓ |
✓ |
|
✓ |
THF |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
Toluene |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
DMF |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
✓ |
DMSO |
✓ |
✓ |
✓ |
|
✓ |
✓ |
|
|
✓ |
Ether |
✓ |
✓ |
✓ |
|
|
✓ |
✓ |
|
✓ |
DCM |
✓ |
|
✓ |
✓ |
|
✓ |
✓ |
|
✓ |
Alcohols (ethanol) |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
✓ |
Acetic acid |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
✓ |
Acetone |
✓ |
✓ |
✓ |
✓ |
|
✓ |
✓ |
✓ |
✓ |
Phenol |
✓ |
✓ |
✓ |
|
|
✓ |
✓ |
✓ |
✓ |
Cyclohexane |
✓ |
|
✓ |
|
|
✓ |
✓ |
|
✓ |
Septa compatibility with applications
This table provides a summary of the suitability of our septa materials to a variety of applications.
|
PTFE |
PTFE/silicone |
PTFE/silicone/PTFE |
Viton |
Silicone |
Silicone/FEP |
Silicone/polyimide |
Butyl |
Natural rubber |
---|---|---|---|---|---|---|---|---|---|
Temperature range |
Up to 260°C |
-40°C to 250°C |
-40°C to 250°C |
-40°C to 260°C |
-40°C to 250°C |
-40°C to 250°C |
-40°C to 300°C |
-50°C to 150°C |
0°C to 90°C |
Multiple injections |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
No |
No |
Price |
Very economical |
Economical |
Most expensive |
Economical |
Very economical |
Economical |
Expensive |
Economical |
Most economical |
Suitable for storage |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
No |
Yes |
Best for |
|
|
|
|
|
|
|
|
|
Please refer to the brochure (includes part number lists) for more items.
View full product details
Download: Brochure - Septa, caps and liners (product information and part numbers) [PDF]
Also see: Brochure - Septa, caps and liners (portfolio and capabilities)
Also see: Brochure - GC consumables
View full product detailsPrivacy and security | Terms and conditions
© 2021 Trajan Scientific and Medical.